Woodward MRM3

Applicaties

  • Protection for LV and MV motors

Belangrijke specificaties

  • Microprocessor technology with self-supervision
+ Bekijk alle specificaties

Neem contact op over dit product

Reactie binnen één werkdag
Hierin wordt het volgende vermeld over het verwerken van mijn gegevens: De informatie die via de formulieren op de website wordt verzonden wordt niet in het systeem opgeslagen. Deze informatie wordt alleen via e-mail doorgestuurd naar Summit Power.

Productbeschrijving

The motor protection relay MRM3-2 offers reliable protection for LV and MV motors which are either operated via power contactors or power circuit breakers.

Meer informatie

Producteigenschappen

Producttype

Motor beveiliging

Serie

HighTECH

Productomschrijving

The motor protection relay MRM3-2 offers reliable protection for LV and MV motors which are either operated via power contactors or power circuit breakers.

The following functions are integrated into this relay:
• Overload protection acc. to IEC 255-8 in consideration of the initial load factor (thermal image)
• Definite undercurrent protection
• Definite time over current protection (DMT)
• Inverse time over current protection (IMT) with select-able trip characteristics
• Short-circuit protection
• Load unbalance supervision with definite or inverse trip characteristics
• Earth-fault detection with suppression of harmonics

The MRM3-2 recognizes the “Start-Up“ and “Motor Running“ phase. Motors with a limited number of starts can be controlled by the start limiting function of the relay. The earth-fault supervision is either realized in Holm-green connection or by means of a core-type current transformer. The motor can be stopped in delayed or undelayed mode via digital inputs.
The MRM3-2 is available with rated currents of 1A or 5A.

Features
• Microprocessor technology with self-supervision,
• Measuring of phase currents as RMS value,
• Digital filtering of the earth current with discrete Fourier analysis, by which the influence of interference signals, such as harmonics and transient DC components during an earth- fault are suppressed.
• Two sets of parameters,
• Operating hour meter,
• Complies with the requirements of IEC 255-8, VDE435, part 301-1 for overload relays,
• Definite time undercurrent protection,
• Selectable protective functions : Definite time over-current protection (DMT) and inverse time over current protection (IMT)
• Selectable IMT trip characteristics of IEC 255-4:
– Normal inverse (Type A)
– Very inverse (Type B)
– Extremely inverse (Type C)
– Special-purpose characteristics
• Reset mode for DMT/IMT trip characteristics is selectable,
• Definite element for short-circuit high-speed trip
• Single-step earth fault supervision,
• Load unbalance protection with inverse or definite trip characteristics (NPS),
• CB failure protection,
• Display of the measuring values as primary quantities,
• Measuring of the phase currents during short-circuit free operation,
• Blocking of the individual protective elements or the trip elements can be set freely,
• The protective functions can be freely allocated to the output relays. (Relay Matrix),
• Suppression of an LED indication after activation (LED flash),
• „Manual/Automatic“ reset function of the trip elements adjustable via the configuration matrix,
• Saving of trip values and the switch-off times (tCBFP) of 25 fault events (voltage fail-safe)
• Recording of up to 8 fault events with time stamp,
• Display of date and time,
• Trip via digital inputs,
• Rack mounting, with self-acting short-circuit mechanism for CT circuits,
• Possibility of serial data exchange via the RS485 interface, optionally with SEG Electronics RS485 Pro-Open-Data Protocol or Modbus Protocol.