SEG-MRN3

Applicaties

  • Over/ and under voltage and frequency protection

Belangrijke specificaties

  • Extremely fast decoupling of generator
+ Bekijk alle specificaties

Neem contact op over dit product

Reactie binnen één werkdag
Hierin wordt het volgende vermeld over het verwerken van mijn gegevens: De informatie die via de formulieren op de website wordt verzonden wordt niet in het systeem opgeslagen. Deze informatie wordt alleen via e-mail doorgestuurd naar Summit Power.

Productbeschrijving

A universal mains decoupling device and covers the protection requirements from VDEW and most other utilities for the mains parallel operation of power stations.

Meer informatie

Producteigenschappen

Producttype

Netontkoppeling

Productomschrijving

Because of combination of three protection functions in one device the MRN3 is a very compact mains decoupling device. Compared to the standard used single devices it has a very good price/performance ratio.

Features
• Microprocessor technology with watchdog,
• effective analog low pass filter for suppressing harmonics when measuring frequency and vector surge,
• digital filtering of the measured values by using discrete Fourier analysis to suppress
• higher harmonics and d.c. components induced by faults or system operations,
• integrated functions for voltage, frequency and vector surge in one device as well as single voltage, frequency and vector surge devices,
• two parameter sets,
• voltage supervision each with two step under-/and overvoltage detection,
• frequency supervision with three step under-/or over frequency (user setting),
• completely independent time settings for voltage and frequency supervision,
• adjustable voltage threshold value for blocking frequency and vector surge measuring,
• display of all measuring values and setting parameters for normal operation as well as tripping via a alphanumerical display and LEDs,
• display of measuring values as primary quantities
• Storage of trip values and switching-off time (tCBFP) of 5 fault occurrences (fail-safe of voltage),
• recording of up to eight fault occurrences with time stamp
• for blocking the individual functions by the external blocking input, parameters can be set according to requirement,
• user configurable vector surge measurement 1-of-3 or 3-of-3,
• reliable vector surge measuring by exact calculation algorithm,
• suppression of indication after an activation (LED flash),
• free assignment for output relays,
• display of date and time,
• in compliance with VDE 0435, part 303 and IEC 255,
• serial data exchange via RS485 interface possible; alternatively with SEG Electronics RS485 Pro-Open Data Protocol or Modbus Protocol.