The SEG Electronics MRR1 combines rotor earth fault protection, excitation over and undercurrent protection as well as rotating diode failure protection.

Meer informatie

Producteigenschappen

Producttype

Generator beveiliging, Mono functie

Productomschrijving

The generator rotor protection relay MRR1 combines rotor earth fault protection, excitation over and undercurrent protection as well as rotating diode failure protection.
Thus providing a powerful protection regarding the rotor of synchronous generators, covering the following ANSI codes:
– 37 DC undercurrent relay
– 40 Field relay
– 58 Rectification failure relay
– 64 Ground detector relay
– 76 DC over current relay

The MRR1 is recommended for synchronous generators and motors above 1 MVA rating. The rotor earth fault element detects high- and low resistance earth faults of the rotor winding. It is equipped with two stages, one for alarm, one for trip.

The excitation current protection element super-vises the DC excitation current of brushless excitor machines. The protective functions are: Undercurrent, over current and ripple detection for diode failure protection.

Features
• Detection of high impedance earth faults with a test frequency of 0.5 Hz
• Short circuit and overvoltage proof measuring input for the earth fault protection
• Excitor current measurement galvanically isolated via Hall-transducer, measuring range to 20 A
• Display of insulation resistance
• Display of the excitation current
• Excitation current over- and undercurrent protection with independent settings for current nd delay time
• Detection of diode failures by supervision of the ripple component of the excitation current
• Two stage supervision of the rotor insulation resistance with independent settings for esistance and time delay
• Two trip relays, one for excitation under- and over current, one for diode failure detection
• Digital inputs for blocking and for remote reset
• Programmable function of the blocking input
• Programmable assignment of protective functions to output relays
• Remote interfacing via RS485